Creating Smart Machines

Detecting Moisture, Temperature and Vibration Issues Before They Become Problems

Turck's new cabinet condition monitor - cabinet guard is capable of monitoring moisture and temperature limits while also detecting incorrectly closed doors. As an added benefit, the device monitors unauthorized access to switch cabinets, providing protection against manipulation in compliance with IT security regulations. The slim 12.5 mm DIN-rail cabinet guard can be easily installed in existing switch cabinets due to its compact design.


    • Two potential-free contacts
    • Temperature detection
    • Moisture detection
    • Detection of distance to cabinet door
    • IO-Link parameterizable
    • Connection of two devices via CAN bus
    • Galvanic isolation of outputs (A1/A2)
    • Removable screw terminals

The IM12-CCM features an internal data logger with time stamp and stores data for up to two years, allowing users to detect creeping changes over long periods of time. An interface enables two cabinet guards to be operated in master-slave mode simultaneously, monitoring the data of the slave and sends a signal to the controller.

The standard IM12-CCM comes with two switch contacts and an IO-Link interface. Quick teach mode enables the user to set the limit values easily in the field. Alternatively, the parameters can be set via IO-Link or an FDT framework such as PACTware. 

For hazardous areas use the IMX12-CCM module.

Friday, January 24, 2014

TURCK HL Receptacle Extension Simplifies Connections in CI D1 Areas

TURCK introduces the HL (Hazardous Location) receptacle extension providing users with a connectivity solution for Class I Division 1 (CI D1) locations without the need to install conduits and poured seals. The HL receptacle extension also eliminates the need for intrinsic safety barriers by providing fully encapsulated housings joined by a welded aluminum armored cable available in lengths up to 20 meters.

The extension threads into the conduit entry of the device in a CI D1 hazardous location and extends the connector into a Class I Division 2 (CI D2) area where it can be easily mated with a minifast connector. Due to the use of MC-HL cable and the explosion blocking qualities of the housings, this product has been FM approved for use in CI D1 areas without the need for installing conduit and poured seals or intrinsic safety barriers.  

The HL receptacle extension offers a solutions for oil and gas applications in hazardous areas that was previously not available. This is an ideal solution for those looking for an easier, safer and more cost effective way to connect devices without needing a barrier or poured seals.